200 KVA Diesel Generator (Canopy)

B200SE3-AU

Advantage
− Low fuel consumption
− Optimized system
− High reliability
− High availability
− Long maintenance cycle
Design standards
− Conformite Europeene CE)
− ISO8528-5:2005
− GB/T2820.5-2009

SKU: B200SE3-AU Category:

Description

Diesel Generator Set,Powered by Baudouin

Main Specification
Advantage
− Low fuel consumption
− Optimized system
− High reliability
− High availability
− Long maintenance cycle
Design standards
− Conformite Europeene CE)
− ISO8528-5:2005
− GB/T2820.5-2009
Environmental operating conditions
− Installation place: indoor (well ventilated)
− Ambient temperature: -25℃ to 50℃ (the coolant heater
is needed when the temperature is below 5℃)
− Humidity: Less than 90%
− Altitude: Below one thousand (1000) meters.
Performance guarantee
− Product design, manufacturing and performance
integrity verified by standards
− Generator set passed transient response test
according to ISO8528-5
− Both engine and alternator are prototype and factory
tested
Service support
− Provide global product service support
Factory inspection
− Protection devices working test
− Starting ability in normal temperature
− 50% rated power load moment capability
− Voltage deviation and speed variation: 0, 25%, 50%,
75%, 100%, 110%

Power System
Engine
Manufacturer Baudouin Intake system Turbocharged
Model 6M16G220/5 Intake resistance: kPa ≦7.0
Cylinders and arrangement 6L Back power: kPa ≦6.0
Bore: mm 126 Oil capacity: L 22
Stroke: mm 130 Coolant capacity: L 42
Displacement: L 9.7 Battery voltage: V 24
Compression ratio 17 Dimensions: mm 1983×1033×1264
Rotate speed: RPM 1500 Dry weight: kg 1034
Prime power: kWm 187
Standby power: kWm 204
Rotate speed governor EFC
Type of injection Direct

Alternator
Manufacturer PowerLink Insulation class H
Model PL3F Temperature rising class H
Exciter PMG Drip proof IP23
AVR model MX321 Overspeed: RPM 2250
Windings 100% copper Voltage regulation ±0.5%
Winding pitch 2/3 Telephone harmonic factor THF <2%
Number of poles 4 Telephone interference factor TIF <50
Terminals 12

Control System
Manufacturer POWERLINK
Model PLC7420

General functions Monitoring and protection
− Automatic start/stop control
− Manual/remote start control
− Automatically start when mains is abnormal (AMF)
− Real time monitoring and display of multiple parameters
− RS232, RS485 port and ethernet can be used
− CAN and Modbus communication
− Provide complete control solutions
Oil pressure Overload
Water temperature Overcurrent
Rotate speed Overvoltage
Start Undervoltage
Running time Overfrequency
Battery voltage Underfrequency

(Data Sheet)         200Kva Generator Baudouin Eng Leroy Somer alternator